Switchgear Cabinet
DFW series cable branch boxes

Cable distribution boxes are equipment widely used in the cabling projects of power distribution systems in recent years. They are extensively applied in power grid projects in various places such as industrial parks, residential communities, densely populated urban areas, commercial centers, and high-rise buildings.


  • Product Details

Description

Cable distribution boxes are equipment widely used in the cabling projects of power distribution systems in recent years. They are extensively applied in power grid projects in various places such as industrial parks, residential communities, densely populated urban areas, commercial centers, and high-rise buildings.

The main features of Mohu European-style cable branch boxes are two-way opening doors, using butt sleeves as connecting busbars, with significant advantages such as short length, clear cable arrangement, and no need for large-span crossing of three-core cables. The cable joints used in it comply with the DIN47636 standard. Generally, bolt-fixed cable joints with a rated current of 630A are adopted.

Mohu American-style cable branch boxes are mainly characterized by one-way opening doors and horizontal multi-way busbars, with significant advantages such as small width, flexible combination, full insulation, and full sealing. According to the rated current, they can generally be divided into two types: a 600A main circuit and a 200A branch circuit. The 600A main circuit adopts screw-in bolt-fixed connection, and the 200A branch circuit adopts plug-in connection and can be plugged and unplugged under load.


Technical Standards

GB/T2900.10 Electrical Engineering Terminology - Cables [GB/T2900.10-2001, IEC60050(461):1984, IDT]

GB/T2900.20 Electrical Engineering Terminology - High - voltage Switchgear [GB/T2900.20-1994, IEC60050(IEV):1984, NEQ]

GB3906 - 2006 3.6kV~40.5kV AC Metal - enclosed Switchgear and Controlgear

GB4208 - 2008 Degree of Protection Provided by Enclosures (IP Code) [GB4208 - 2008, IEC 60529:2001, IDT]

GB/T7354 Partial Discharge Measurement [GB/T7354 - 2003, IEC 60270:2000, IDT]

GB/T 11022 Common Technical Requirements for High - voltage Switchgear and Controlgear Standards [GB/T11022 - 2011, IEC 62271 - 1:2007, MOD]

GB/T 16927.1 High - voltage Test Techniques - Part 1: General Definitions and Test Requirements [GB/T 16927.1 - 2011, IEC60060 - 1:2006, MOD]

DL/T404 3.6kV~40.5kV AC Metal - enclosed Switchgear and Controlgear

DL/T593 Common Technical Requirements for High - voltage Switchgear and Controlgear Standards

IEC 62262:2002 Degrees of Protection Provided by Enclosures for Electrical Equipment Against External Mechanical Impacts (IK Code) [Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (lK code)]


Service Environment

1. Ambient Temperature: Maximum temperature +40℃, minimum temperature - 30℃

2. Wind Speed: Equivalent to 34m/s (not more than 700Pa)

3. Humidity: Daily average relative humidity not more than 95%rh, monthly average relative humidity not more than 95%rh

4. Seismic Resistance: Horizontal acceleration not more than 0.4m/s², vertical acceleration not more than 0.15m/s². Inclination of the installation site: not more than 3°

5. Installation Environment: The surrounding air should not be significantly polluted by corrosive, flammable gases, water vapor, etc. The installation site has no severe vibration.

Note: Please consult our company when the order of this product exceeds the above - mentioned conditions.


Functions and Features

1. Fully insulated and fully sealed to ensure personal safety.

2. Outdoor type, dust - proof, moisture - proof, flood - resistant, corrosion - resistant, and highly adaptable to the environment.

3. Flexible combination, with incoming and outgoing lines ranging from two to six, meeting various wiring requirements.

4. Small size, compact structure, beautiful appearance, easy installation, and maintenance - free.

5. Can be equipped with a live - line indicator.

6. Can be equipped with a short - circuit indicator.

7. Can be equipped with a lightning arrester.


Technical Parameter Table of Cable Branch Box

Technical Parameter Table of 10kV European - style Cable Branch Box

Serial number

Project

unit

Parameters

1

Rated voltage

kV

11

2

Rated current

A

630

3

Dynamic stability current

kA/s

50/0.3

4

Thermal stable current

kA/s

20/3

5

1 - minute power - frequency withstand voltage

kV

42

6

15 - minute DC withstand voltage

kV

52

7

Lightning impulse withstand voltage

kV

75

8

Enclosure protection level


IP33

 

Ordering Instructions

The following information should be provided when placing an order:

* Product model name, order quantity, rated voltage, and rated current;

* Model of the operating mechanism. When electric operation is selected, indicate the operating voltage;

* Name and quantity of spare parts;

* For any other special requirements, please contact our company.

Tags:
Share:
Hot Products
Leave a Message
  • WeChat
    Scan the QR Code with WeChat
    Leave a message